A product of NIT · Visit NIT
GlucoState
Continuous glucose monitoring A Saudi brand

Understandingglucose,not just measuring it.

GlucoState® reads your glucose every 3 minutes for 15 days, and turns the numbers into clear, calm insight — on your phone, and with your care team.

Factory-calibrated15-day wearA reading every 3 minutes

The GlucoState single-use applicator. The GlucoState sensor.
Single-use applicator1.75 g sensor

Better insights. Better control.

رؤية أوضح وتحكم أفضل

At a glance

Small. Light. Precise.

A sensor smaller than you expect, with the accuracy your care team needs.

<8.3 %
MARD accuracy
Across low, normal and high glucose ranges.
15 days
Per sensor
Factory-calibrated, with no fingerstick calibration.
The GlucoState sensor.
1.75 g
Sensor weight
Ultra-low profile with a hypoallergenic adhesive.
IPX8
Water-resistant
Rated for water and dust resistance.
Product family · GlucoState®

Made for everyday life.

Sensor, applicator and app — one quiet system that works in the background, so you can get on with your day.

The GlucoState app on a phone, beside the applicator and sensor.
How it works

Wear. See. Analyse. Act.

Four simple moves turn continuous data into decisions.

  1. Exploded view of the applicator and sensor.
    1Wear

    The single-use applicator places the 1.75 g sensor in one step. It stays on, water-resistant, for up to 15 days. [CONFIRM WEAR SITE]

  2. The GlucoState app on a phone, beside the applicator and sensor.
    2See

    A new reading every 3 minutes on your phone, with the trend and time in range at a glance. No fingerstick calibration. [CONFIRM WARM-UP TIME]

  3. 3Analyse

    AI reads your glucose patterns and flags trends early, turning a stream of numbers into clear daily insight.

  4. A Saudi clinician shows a patient her glucose data on a tablet in a calm, daylight clinic.
    4Act

    Make informed choices day to day, and share reports with your care team whenever you choose.

A day with GlucoState®

Twenty-four hours, one clear picture.

Drag through a typical day to see what the sensor picks up, and what the app tells you.

180 · Target range 70–180 70
7:45 AMHigh alert
191mg/dL
Breakfast

Glucose climbs above 180 mg/dL. A high alert arrives with the trend, so you know which way it’s heading.

Time in range so far97%

Illustrative data for a typical day. Not a real patient record, and not medical advice.

The GlucoState® app

Every reading tells a story.

See where your glucose is, where it is heading and how your day affects it. Choose a screen to look inside the app.

Your glucose, at a glance

The current reading with its trend, your sensor’s status and time left, the glucose curve over 3 to 24 hours, and today’s time in range and average.

  • Real-time readings
  • Predictive alerts
  • Share with caregivers
  • Clinic-ready reports
Coming soon to the App Store and Google Play
Download on the App Store Get it on Google Play
Why continuous

Beyond the fingerstick.

A fingerstick meter gives you a single moment. GlucoState® shows the whole story.

Fingerstick meterGlucoState®
ReadingsOnly when you testEvery 3 minutes, automatically: 480 a day
Finger pricksEvery testNone for calibration*
TrendsA single numberTrend arrows and a 24-hour curve
AlertsNoneHigh and low glucose alerts
OvernightNot while you sleepContinuous, through the night
SharingA logbook, or memoryReports for your care team

*GlucoState® is factory-calibrated. A fingerstick check is still advised when symptoms don’t match sensor readings.

In the box

Two parts. One step.

The GlucoState single-use applicator.
Applicator
  • Single-use
  • Places the sensor in one step
  • [CONFIRM INSERTION DETAILS]
The GlucoState sensor.
Sensor
  • 1.75 g, ultra-low profile
  • 15-day wear, IPX8 water resistance
  • Bluetooth Low Energy to the app
Clinical performance

Accuracy you can check.

Factory-calibrated accuracy across the full glucose range. Full study details are available to healthcare professionals on request.

Overall MARD
<8.3%
Against reference blood glucose [CONFIRM REFERENCE METHOD]
To be confirmed
Below 70 mg/dL
Low range
To be confirmed
70–180 mg/dL
Target range
To be confirmed
Above 180 mg/dL
High range
Within ±20% / 20 mg/dLTo be confirmedof readings
Consensus Error Grid A+BTo be confirmedof readings
Study designTo be confirmedParticipants · sites · 15-day wear
Request the full study
Specifications

The details, in full.

Everything GlucoState® is made of, measured by and tested against.

Sensor

Small, light and factory-calibrated — built to be worn and forgotten for 15 days.

<8.3%
MARD accuracy across low, normal and high glucose ranges
Wear period
15 days per sensor
Readings
Every 3 minutes, with trend arrows
Calibration
Factory-calibrated, no fingerstick calibration
Weight
1.75 g
Profile
Ultra-low, hypoallergenic adhesive
Water resistance
IPX8
Accuracy (MARD)
Under 8.3%
Warm-up
[X] minutes
ISO 13485ISO 14971ISO 10993IEC 60601-1
Request full test reports
Questions

Clear answers, before you ask.

Something not covered here? Ask our team.

Ask our team

Each GlucoState® sensor is worn for 15 days, then replaced with a new one.

For clinicians and partners

See GlucoState® for yourself.

Request product information, test reports or evaluation samples.